Program, sequence, protect, and condition your system’s power
Sequencing is needed when various types of electronic equipment must be powered up or down in order, rather than simultaneously. In AV systems, sequencing is often necessary for controlling the distribution of mains power to avoid equipment damage.
SurgeX Sequencers provide the sequencing parameters, conditioning, shutdown thresholds, and surge protection needed to safeguard audio, video, broadcast, and computer equipment. These units have robust management features and are extremely easy to install, program, and use. They include two always-on receptacles and four programmable banks. The SEQ models feature one “virtual” bank for controlling remote units, allowing for infinitely expanding distribution schemes.
They are engineered with Advanced Series Mode surge elimination technology to provide top-of-the-line protection. Superior to conventional MOV circuitry or MOV-Hybrid designs, they completely eliminate surge energy up to 6,000 volts without producing harmful side effects such as earth contamination or common-mode disturbances. Completely non-sacrificial and never needing reset, they provide the most reliable protection available. Our Sequencers also feature both common mode and normal mode Impedance Tolerant EMI/RFI filtering, SurgeX ICE (Inrush Current Elimination), and COUVS (Catastrophic Over/Under Voltage Shutdown) for a complete mains power conditioning solution.
SPECIFICATIONS SEQ-1216i
Load Rating 16A
Voltage Rating 220-240V
Power Requirement (no load) 8 W
Input/Mains Plug Type CEE7/7
Input/Mains Cord Length 2.4m / 8'
# of Receptacles 10
Receptacle Type IEC C13
Surge Let-through Voltage (6000 Volt Surge) 0 VoltsMaximum Applied Surge Voltage 6000 Volts *
Maximum Applied Surge Current Unlimited (due to current limiting) *
Maximum Applied Surge Energy Unlimited (due to current limiting) *Endurance (C62.41-1991 category B3 pulses) 1 KV > 500,000; 3 KV > 10,000; 6 KV > 1000
EMI/RFI Filter
Normal mode (500 load) 40 dB © 100 kHz; 50 dB @ 300 kHz; 50 dB @ 3 MHz; 50 dB © 30 MHz
Common Mode (500 load) 18 dB @ 300 kHz; 30 dB © 1 MHz; 50 dB © 5 MHz; 50 dB © 20 MHzUnder-Voltage Auto Shutdown 180V
Over-Voltage Auto Shutdown 280VOver-Current Auto Shutdown Circuit Breaker
Over-Temperature Auto Shutdown None
Network Port No
Serial Port None Temperature
Sensor Input NoneBTU/h Max 130 BTU/h
Auxiliary Relay Outputs 2 x screw terminal
Contact Closure Input 2 x screw terminalDimensions 44.45mm H x 482.60mm W x 266.70mm D/ 1.75"H x 19"W x 10.5"D
Weight 5.9 kg / 13 lbs
Temperature Range: 5C to 35C
Humidity Range 5% to 95% R.H.Non-condensing Agency Listings
Certified to IEC/EN 61643-1* 1.2 x 50 microsecond industry standard combination wave surge as per IEEE C62.41
** Specifications subject to change without notice
Specifications Version: ESP-SRX_Product_Specs_Master 01.30.20.xlsx